SDS Volume (3036)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 464

Original Measurements

Leighton, D. T.; Calo, J. M.; J. Chem. Eng. Data 1981, 26, 382-5.

Variables:

Room Temp: 274 - 299 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A 5 µL trichloroethene sample was injected into a 2.3 L equilibration cell containing distilled water. After the cell was shaken vigorously for about 5 minutes, the homogeneity of the liquid sample was maintained with a magnetic stirrer. Compressed air was passed through the cell and the gas flow was measured with a soap film flowmeter. The trichloroethene content was extracted and analyzed using a dual flame ionization detector gas chromatograph.

Source and Purity of Materials:
  1. Source and purity not given.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±2.1%.

Components:
  1. Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ DL
1.0 0.15762.164 x 10-4131.6
1.0 0.14872.041 x 10-4139.5
1.2 0.14942.051 x 10-4138.8
2.5 0.13391.838 x 10-4168.4
7.0 0.14341.968 x 10-4200.9
10.0 0.14501.991 x 10-4232.7
12.0 0.14682.016 x 10-4254.8
12.0 0.14081.933 x 10-4265.8
12.9 0.13721.884 x 10-4287.0
14.0 0.13371.836 x 10-4309.9
18.0 0.13481.851 x 10-4375.0
18.0 0.13321.329 x 10-4379.6
18.0 0.13401.851 x 10-4375.0
19.0 0.13501.853 x 10-4393.5
19.2 0.12731.749 x 10-4417.3
19.5 0.13721.884 x 10-4396.5
24.3 0.12851.764 x 10-4537.1
25.2 0.13091.797 x 10-4539.9
25.3 0.13251.819 x 10-4545.7
26.0 0.13431.844 x 10-4551.1
26.0 0.13131.802 x 10-4563.8
26.1 0.13261.820 x 10-4558.1

(a) Gas-liquid system analysis parameter, from calibration measurements.

Download Data   link to XML output link to JSON output link to JSON-LD output