SDS Volume (3030)
Volume 67. Halogenated Ethanes and Ethenes with Water, p 461
Original Measurements
Halliday, M. M.; MacDonald, I.; MacGregor, M. H. G.; Br. J. Anaesth. 49, 413 (1977).
Variables:
Room Temp: 310 $\pu{K}$
Prepared by:
Method/Apparatus/Procedure:
A constant flow of trichloroethene vapor was bubbled through water, allowing 45 minutes for equilibration. The concentration in the gas mixture was in the range 0.5-2 % (v/v) trichloroethene. A Riken 18A refractometer provided accurate estimations of gaseous concentrations of trichloroethene. Five samples of aqueous solutions were analyzed by gas chromatography. The chromatograph was equipped with a flame ionization detector and potentiometric recorder.
Source and Purity of Materials:
- ICI Pharmaceuticals, used as received.
- Distilled.
Estimated Errors:
Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): ±0.02 SEM.
Components:
- Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | 100w1 | $x_{1}$ | $L$ |
|---|---|---|---|
| 36.85 | 0.141 | 1.94 x 10-4 | 1.64 |