SDS Volume (3030)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 461

Original Measurements

Halliday, M. M.; MacDonald, I.; MacGregor, M. H. G.; Br. J. Anaesth. 49, 413 (1977).

Variables:

Room Temp: 310 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A constant flow of trichloroethene vapor was bubbled through water, allowing 45 minutes for equilibration. The concentration in the gas mixture was in the range 0.5-2 % (v/v) trichloroethene. A Riken 18A refractometer provided accurate estimations of gaseous concentrations of trichloroethene. Five samples of aqueous solutions were analyzed by gas chromatography. The chromatograph was equipped with a flame ionization detector and potentiometric recorder.

Source and Purity of Materials:
  1. ICI Pharmaceuticals, used as received.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): ±0.02 SEM.

Components:
  1. Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ $L$
36.85 0.1411.94 x 10-41.64

Download Data   link to XML output link to JSON output link to JSON-LD output