SDS Volume (3028)

Volume 67. Halogenated Ethanes and Ethenes with Water, p 460

Original Measurements

Chiou, C. T.; Freed, V. H.; "Chemodynamic Studies on Bench Mark Industrial Chemicals"; NTIS: Springfield, VA, 1977; PB-274263.

Variables:

Room Temp: 267 - 307 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

An excess of 5-10 g trichloroethene was equilibrated with 100 mL of distilled water for 24 hours in a bottle. The aqueous solution taken from the bottle was analyzed using a gas chromatograph equipped with a $\ce{^{63}Ni}$ electron capture detector. The GLC column was packed with porous polymer Chromosorb 101. Further details on determination and evaluation of the procedure are found elsewhere [1].

Source and Purity of Materials:
  1. Commercial reagent, used as received.
  2. Distilled.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): Not specified.

References

1 Chiou, C. T.; Schmedding, D. W.; Test. Protoc. Environ. Fate Mov. Toxicants, Proc. Symp., 1980, pp 28-42.

Components:
  1. Trichloroethylene, $\ce{ C2HCl3 }$; [79-01-6] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$
3 0.1782.44 x 10-4
20 0.1502.06 x 10-4
34 0.1472.02 x 10-4

Download Data   link to XML output link to JSON output link to JSON-LD output