Compilation - Methylcyclopentane with Water (IUPAC SDS Volume 37)
SDS Volume (302)
Volume 37. Hydrocarbons in Water and Seawater, Part I, p 215
Original Measurements
Variables:
Room Temp: 10 - 30 °C
Prepared by:
M.C. Haulait-Pirson, A. Maczynski
Method/Apparatus/Procedure:
Component (1) was introduced into a thermostatted flask and saturated for 5 hrs. with (2). Next, calcium hydride was added and the evolving hydrogen volume measured and hence the concentration of (2) in (1) was evaluated.
Source and Purity of Materials:
- Not specified.
- not specified.
Estimated Errors:
Ambient temperature: Not specified.
Components:
- Methylcyclopentane, $\ce{ C6H12 }$; [96-37-7] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
Solubility of water in methylcyclopentane
| $T$ (°C) | MR2 (g1/100 g2) | $x_{2}$ |
|---|---|---|
| 10 | 0.073 | 3.4 x 10-4 |
| 20 | 0.0131 | 6.12 x 10-4 |
| 30 | 0.0205 | 9.58 x 10-4 |