SDS Volume (2791)

Volume 62. Carbon Dioxide in Water and Aqueous Electrolyte Solutions, p None

Original Measurements

Murray, C. N.; Riley, J. P.; Deep-Sea Res. 1971, 18, 533-41.

Variables:

Room Temp: 274.19 - 308.15 $\pu{K}$
Pressure: 101.325 $\pu{kPa}$

Prepared by:

R. Crovetto

Method/Apparatus/Procedure:

Equilibrated solutions were prepared by bubbling gas through magnetically stirred water till equilibrium was reached.
The $\ce{CO2}$ content was determined by acidifying the solutions and after degassing then, precisely weighing the evolved $\ce{CO2}$.

Source and Purity of Materials:
  1. 99.9%, tested by mass spectrometry.
  2. Conductivity water, degassed.
Estimated Errors:

Ambient temperature: δT/K = ±0.02 (by authors)

Components:
  1. Carbon dioxide, $\ce{ CO2 }$; [124-38-9] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ ($\pu{K}$) $T$ (°C) $x_{1}$ α ($\pu{cm3(g) cm-3(l) atm-1}$) $P_{\rm{c}}$ ($\pu{bar}$)
274.191.04 1.331 x 10-31.6471 1.020
278.155.00 1.148 x 10-31.4199 1.022
283.1510.00 9.645 x 10-41.1926 1.026
288.1515.00 8.174 x 10-41.0100 1.030
293.1520.00 7.009 x 10-40.8652 1.037
298.1525.00 6.099 x 10-40.7519 1.045
305.1532.00 5.150 x 10-40.6336 1.061
308.1535.00 4.805 x 10-40.5905 1.070

(a) Calculated by the compiler.

(b) Bunsen coefficient [cm3 (STP) cm-3 atm-1].
The results are the mean of at least three measurements.

Download Data   link to XML output link to JSON output link to JSON-LD output