SDS Volume (2782)

Volume 62. Carbon Dioxide in Water and Aqueous Electrolyte Solutions, p None

Original Measurements

Yeh, S-Y.; Peterson, R. E.; J. Pharm. Sci. 1964, 53, 822-4.

Variables:

Room Temp: 298.15 - 318.15 $\pu{K}$
Pressure: 101.325 $\pu{kPa}$

Prepared by:

R. Crovetto

Method/Apparatus/Procedure:

The method and apparatus used are described in [1] with two minor modifications: the mercury sealing cup was eliminated in the new version and the gas was presaturated with water vapor.

Source and Purity of Materials:
  1. Research grade Matheson Co. Minimum purity 99.7%.
  2. Redistilled from all glass still. Degassed.
Estimated Errors:

Ambient temperature: δT/K = ±0.05
Mass concentration (m/v) (1): δL = ±1% (authors)
Pressure: δP/mmHg = ±2
(δP/bar = ±0.003)

References

1 Yeh, S-Y.; Peterson, R. E.; J. Pharm. Sci. 1963, 52, 453-458.

Components:
  1. Carbon dioxide, $\ce{ CO2 }$; [124-38-9] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ ($\pu{K}$) $T$ (°C) $x_{1}$ $P$ ($\pu{bar}$) $L$
298.1525 5.842 x 10-41.0130.8129
303.1530 5.084 x 10-41.0130.7264
310.1537 4.215 x 10-41.0130.6282
318.1545 3.153 x 10-41.0130.5453

(a) Calculated by the compiler.

(b) Experiments ere done at a total pressure equal to atmospheric pressure.

(c) L = Ostwald coefficient [cm3 cm-3].

Download Data   link to XML output link to JSON output link to JSON-LD output