SDS Volume (2779)

Volume 62. Carbon Dioxide in Water and Aqueous Electrolyte Solutions, p None

Original Measurements

Austin, W. H.; Lacombe, E.; Rand, P. W.; Chatterjee, M.; J. Appl. Physiol. 1963, 18, 301-4.

Variables:

Room Temp: 293.2 - 311.2 $\pu{K}$

Prepared by:

C.L. Young

Method/Apparatus/Procedure:

Humidified gas dissolves in water. After equilibrium established 1 mL sample withdrawn and analyzed with manometric Van Slyke apparatus. It was claimed that deionised, distilled water gave the same results as acidified water.

Source and Purity of Materials:
  1. Commercial sample, no othe details given.
  2. Distilled acidified with hydrochloric acid (0.01 mol dm-3).
Estimated Errors:

Ambient temperature: δT/K = ±0.1

Components:
  1. Carbon dioxide, $\ce{ CO2 }$; [124-38-9] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ ($\pu{K}$) α ($\pu{cm3(g) cm-3(l) atm-1}$) αrange ($\pu{cm3(g) cm-3(l) atm-1}$)
293.2 0.76413.7 x 10-3
297.2 0.65035 x 10-4
303.2 0.58253.9 x 10-3
308.2 0.54533.8 x 10-3
311.2 0.85682.1 x 10-3