Components:

(1) Carbon dioxide, CO2; [124-38-9] NIST WebBook
(2) Water, H2O; [7732-18-5] NIST WebBook

Original Measurements

Van Slyke, D. D.; J. Biol. Chem. 1939, 130, 545-54.

Variables:

Ambient temperature: 295.95 - 298.65 K
Pressure: 101.325 kPa

Prepared by:

R. Crovetto

Method/Apparatus/Procedure:

Measurements were made in a Van Slyke/Neill apparatus.1,2 In this kind of apparatus the equilibration and analysis were done in the same chamber. Shaking was done during saturation and degassing. Once equilibration was achieved the undissolved gas was removed and the solution analyzed for absorbed gases manometrically in a known volume.

Source and Purity of Materials:
  1. 99.9%.
  2. Not specified. Degassed.
Estimated Errors:

Ambient temperature: Not stated.

References

1 Van Slyke, D. D.; Neill, J. M.; J. Biol. Chem. 1924. 61, 523-35.
2 Van Slyke, D. D.; J. Biol. Chem. 1927, 73, 121-24.

Experimental Values:
T (K) T (°C) x1 P (atm) α (cm3(g) cm-3(l) atm-1) Pc (bar)a
295.95 22.8 6.534 x 10-4 1.0 8.06 x 10-1 1.041
295.95 22.8 6.542 x 10-4 1.0 8.07 x 10-1 1.041
297.85 24.7 6.197 x 10-4 1.0 7.64 x 10-1 1.044
297.95 24.8 6.148 x 10-4 1.0 7.58 x 10-1 1.045
298.55 25.4 6.101 x 10-4 1.0 7.52 x 10-1 1.046
298.65 25.5 6.109 x 10-4 1.0 7.53 x 10-1 1.046

(a) Calculated by the compiler. (b) α = Bunsen coefficient [cm3 (STP) cm-3 atm-1]. (c) Assuming that Vm,1 = 22.2605 dm3 mol-1 at STP.

Download Data   link to XML output link to JSON output link to JSON-LD output