Components:
(1) Benzene,
C6H6; [71-43-2]
NIST WebBook
(2) Water,
H2O; [7732-18-5]
NIST WebBook
Original Measurements
Sanemasa, I.; Arakawa, S.; Araki, M.; Deguchi, T.; Bull. Chem. Soc. Jpn. 1984, 57, 1539-44.
Variables:
Ambient temperature: One temperature: 25 °C
Prepared by:
Method/Apparatus/Procedure:
The apparatus used is described in detail in ref 1. The method involves the introduction of solute vapor (1) into liquid (2) by bubbling air through liquid (1) using a recirculating pump in a closed system. After solubility equilibrium was attained an aliquot of the saturated aqueous solution was withdrawn and analyzed by solvent extraction - UV spectrophotometry.
Source and Purity of Materials:
- Analytical reagent grade source and purity not stated, used without further purification.
- Deioized and redistilled; no further details given
Estimated Errors:
Ambient temperature: not specified.
References
1 Sanemasa, I.; Araki, M.; Deguchi, T.; Nagai, H.; Bull. Chem. Soc. Jpn. 1982, 55, 1054-62.