SDS Volume

Volume 62. Carbon Dioxide in Water and Aqueous Electrolyte Solutions, p None

Source Publication

Findlay, A.; Williams, T.; J. Chem. Soc. 1913, 103, 636-45.

Conditions:

Room Temp: 298.15 $\pu{K}$
Pressure: 35.1 - 102.4 $\pu{kPa}$

Compiler:

P. Scharlin

Methodology:

The apparatus was essentially similar to that of Geffcken [1] except that the manometer tube was longer.

Sample Information:
  1. Purity 99.42 mole%.
  2. Degassed by boiling.
Measurement Errors:

Ambient temperature: δT/K = ±0.1
Mass concentration (m/v) (1): δL ±0.25%

Methodology Citation

1 Geffcken, G.; Z. Phys. Chem. 1904, 49U, 257-302.

System Components:
  1. Carbon dioxide, $\ce{ CO2 }$; [124-38-9] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ ($\pu{K}$) $x_{1}$ $L$ $P_{\rm{c}}$ ($\pu{kPa}$)
298.15 2.09 x 10-4a0.817b 35.1
298.15 2.15 x 10-4a0.816b 36.1
298.15 3.02 x 10-4a0.814b 50.9
298.15 3.09 x 10-4a0.811b 52.3
298.15 3.80 x 10-4a0.816b 63.9
298.15 3.92 x 10-4a0.816b 66.0
298.15 5.16 x 10-4a0.816b 86.8
298.15 5.29 x 10-4a0.817b 88.9
298.15 5.97 x 10-4a0.818b 100.3
298.15 6.09 x 10-4a0.817b 102.4

(a) Calculated by the compiler.

(b) L = Ostwald coefficient [cm3 cm-3]

Download Data   link to XML output link to JSON output link to JSON-LD output