SDS Volume (2639)

Volume 62. Carbon Dioxide in Water and Aqueous Electrolyte Solutions, p None

Original Measurements

Findlay, A.; Shen, B.; J. Chem. Soc. 1912, 101, 1459-68.

Variables:

Room Temp: 298.15 $\pu{K}$
Pressure: 100.7 - 180.0 $\pu{kPa}$

Prepared by:

P. Scharlin

Method/Apparatus/Procedure:

The apparatus was essentially similar to that of Geffcken [1] except that the manometer tube was longer.

Source and Purity of Materials:
  1. Purity 99.42 mole%.
  2. Degassed by boiling.
Estimated Errors:

Ambient temperature: δT/K = ±0.1
Mass concentration (m/v) (1): δL = ±0.25%

References

1 Geffcken, G.; Z. Phys. Chem. 1904, 49U, 257-302.

Components:
  1. Carbon dioxide, $\ce{ CO2 }$; [124-38-9] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ ($\pu{K}$) $x_{1}$ $L$ $P_{\rm{c}}$ ($\pu{kPa}$)
298.15 6.06 x 10-40.826 100.7
298.15 6.08 x 10-40.825 101.2
298.15 6.70 x 10-40.825 111.5
298.15 6.75 x 10-40.826 112.1
298.15 7.44 x 10-40.826 123.6
298.15 7.47 x 10-40.824 124.5
298.15 8.54 x 10-40.823 142.5
298.15 8.68 x 10-40.825 144.5
298.15 9.69 x 10-40.825 161.3
298.15 9.70 x 10-40.825 161.5
298.15 1.080 x 10-30.824 180.0
298.15 1.080 x 10-30.826 180.0

(a) Calculated by the compiler.

(b) L = Ostwald coefficient [cm3 cm-3]

Download Data   link to XML output link to JSON output link to JSON-LD output