SDS Volume (2554)
Volume 60. Halogenated Methanes with Water, p None
Original Measurements
Munz, C. D.; Ph.D. Dissertation, Stanford University, Stanford, CA 1985, 306 pp.
Variables:
Room Temp: 283 - 303 $\pu{K}$
Prepared by:
Method/Apparatus/Procedure:
The multiple equilibrium technique with direct aqueous injection into a gas chromatograph was used to determine the dimensionless Henry's law constant. A known volume of liquid and gas was introduced into a syringe and allowed to equilibrate. The ratio of gas to liquid volume was maintained constant. While vapor samples were injected direct into a gas chromatograph, the liquid samples were preconcentrated by liquid-liquid extraction before analysis. The experiments were carried out in duplicates.
Source and Purity of Materials:
- Aldrich Chemicals Co., WI, > 99.5% pure.
- distilled and deionized.
Estimated Errors:
Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±1.28 × 10-2 std. dev.
Components:
- Tetrachloromethane, $\ce{ CCl4 }$; [56-23-5] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | ρ (g/L) | 100w1 | $x_{1}$ | $k_{\rm{D}}$ (m3 atm mol-1) |
|---|---|---|---|---|
| 10 | 0.810 | 0.0810 | 9.493 x 10-5 | 0.609 |
| 20 | 0.784 | 0.0784 | 9.188 x 10-5 | 0.980 |
| 30 | 0.755 | 0.0755 | 8.848 x 10-5 | 1.530 |