SDS Volume

Volume 60. Halogenated Methanes with Water, p None

Source Publication

Rauws, A. G.; Olling, M.; Wibowo, A. E.; J. Pharm. Pharmac. 1973, 25, 718-22.

Conditions:

Room Temp: 298 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

A calibrated bottle was filled with nitrogen, a measured quantity of water, and the organic vapor. After mixing and equilibration, the concentrations of the vapor and the liquid phases were determined by injection of the head space samples into a gas chromatograph. Trichlorofluoromethane was detected by means of a tritium foil electron capture detector.

Sample Information:
  1. Source and purity not given.
  2. Distilled (compiler).
Measurement Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): Not specified.

System Components:
  1. Trichlorofluoromethane, $\ce{ CCl3F }$; [75-69-4] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 $x_{1}$ $mol_{1}/\pu{100 g}$ (mol/g)
25 0.11 1.44 x 10-48.0 x 10-6

Download Data   link to XML output link to JSON output link to JSON-LD output