SDS Volume (2441)

Volume 60. Halogenated Methanes with Water, p None

Original Measurements

Clifford, C. W.; Ind. Eng. Chem. 1921, 13, 631-32.

Variables:

Room Temp: 297 - 302 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

The calcium chloride method was used for the determination of water in the samples. The moisture was abstracted from the samples by air and absorbed in two calcium chloride tubes. The two tubes were weighted before and after desorption. For further details, see [1].

Source and Purity of Materials:
  1. Distilled (compiler).
  2. Technical grade, used after distilling over $\ce{CaCl2}$.
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): about 1 mg.

References

1 Clifford, C. W.; Ind. Eng. Chem. 1921, 13, 628.

Components:
  1. Tetrachloromethane, $\ce{ CCl4 }$; [56-23-5] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) w1 100w1 $mol_{1}/\pu{100 g}$ (mol/g)
24 1.0 x 10-4 0.08535.55 x 10-6
28.5 1.3 x 10-4 0.11097.22 x 10-6

Download Data   link to XML output link to JSON output link to JSON-LD output