SDS Volume

Volume 60. Halogenated Methanes with Water, p None

Source Publication

Gross, P. M.; Saylor, J. H.; J. Am. Chem. Soc. 1931, 53, 1744-51.

Conditions:

Room Temp: 288 - 303 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

An excess of dibromomethane in 50 g water was shaken for 12 hours in a thermostat bath. Samples were then withdrawn and read against water in an interferometer made by Zeiss [1]. A detailed description of the complete procedure is given in a Ph.D. the thesis [2].

Sample Information:
  1. Eastman Kodak Co., purified by fractionation through a Hempel column before use.
  2. distilled.
Measurement Errors:

Ambient temperature: ±0.02 K.
Mass concentration (m/v) (1): ±0.5%.

Methodology Citations

1 Gross, P. M.; J. Am. Chem. Soc. 1929, 51, 2362-6.
2 Saylor, J. H.; Ph.D. Dissertation, Duke University, Durham, NC, 1930.

System Components:
  1. Dibromomethane, $\ce{ CH2Br2 }$; [74-95-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) MR1 (g1/g2) 100w1 a $x_{1}$
15 0.01170 1.161.21 x 10-3
30 0.01193 1.181.24 x 10-3

Download Data   link to XML output link to JSON output link to JSON-LD output