SDS Volume

Volume 60. Halogenated Methanes with Water, p None

Source Publication

Balls, P. W.; Ph.D. Dissertation, Univ. of East Anglia, Norwich, U.K.; July 1980, 375 pp.

Conditions:

Room Temp: 283 - 298 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

The method involved repeated equilibrations of nitrogen with a water sample containing trichlorofluoromrthane. The sample was shaken vigorously at the required temperature in a constant temperature bath for 30 minutes. The equilibrated gas phase was then injected into a gas chromatograph. The experiments were performed at least three times at 10, 15, 20, and 25 °C with each experiment involving about six equilibrations.

Sample Information:
  1. Source and purity not given.
  2. Salinity = 20%.
Measurement Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): See above.

System Components:
  1. Trichlorofluoromethane, $\ce{ CCl3F }$; [75-69-4] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 a $x_{1}$ $k_{\rm{H}}$ (m3 atm mol-1)
10 0.1301.71 x 10-42.82
15 0.1291.70 x 10-43.38
20 0.1301.71 x 10-43.95
25 0.1451.90 x 10-44.15

Download Data   link to XML output link to JSON output link to JSON-LD output