SDS Volume
Volume 60. Halogenated Methanes with Water, p None
Source Publication
Zeininger, H.; Hoechst A. G.; Internat Report, 1975.
Conditions:
Room Temp: 276 - 313 $\pu{K}$
Compiler:
Methodology:
Degassed liquid trichlorofluoromethane samples were introduced into degassed seawater samples up to saturation at which point two phases appeared. After shaking a sample for several hours equilibrium was achieved and the respective phases were analysed with a gas liquid chromatograph.The original report is not obtainable; therefore, the details were taken from Junge [1].
Sample Information:
- Source and purity not given.
- North Atlantic surface water, salinity not given.
Measurement Errors:
Ambient temperature: ±1 K (compiler).
Mass concentration (m/v) (1): Not specified.
Methodology Citation
System Components:
- Trichlorofluoromethane, $\ce{ CCl3F }$; [75-69-4] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | 100w1 | $x_{1}$ | $mol_{1}/\pu{100 g}$ (mol/g) |
|---|---|---|---|
| 3 | 0.19 | 2.50 x 10-4 | 1.38 x 10-5 |
| 10 | 0.12 | 1.58 x 10-4 | 8.74 x 10-6 |
| 20 | 0.09 | 1.18 x 10-4 | 6.55 x 10-6 |
| 40 | 0.05 | 6.56 x 10-5 | 3.64 x 10-6 |