Components:
(1) Trichlorofluoromethane,
CCl3F; [75-69-4]
NIST WebBook
(2) Seawater,
H2O; [7732-18-5(C)]
NIST WebBook
Original Measurements
Zeininger, H.; Hoechst A. G.; Internat Report, 1975.
Variables:
Ambient temperature: 276 - 313 K
Prepared by:
Method/Apparatus/Procedure:
Degassed liquid trichlorofluoromethane samples were introduced into degassed seawater samples up to saturation at which point two phases appeared. After shaking a sample for several hours equilibrium was achieved and the respective phases were analysed with a gas liquid chromatograph.The original report is not obtainable; therefore, the details were taken from Junge (ref. 1).
Source and Purity of Materials:
- Source and purity not given.
- North Atlantic surface water, salinity not given.
Estimated Errors:
Ambient temperature: ±1 K (compiler).
Mass concentration (m/v) (1): Not specified.
References
Experimental Values:
| T (°C) | 100w1 | x1 | 100w1M1-1 (mol/g) |
|---|---|---|---|
| 3.0 | 1.9 x 10-1 | 2.50 x 10-4 | 1.38 x 10-5 |
| 10.0 | 1.2 x 10-1 | 1.58 x 10-4 | 8.74 x 10-6 |
| 20.0 | 9 x 10-2 | 1.18 x 10-4 | 6.55 x 10-6 |
| 40.0 | 5 x 10-2 | 6.56 x 10-5 | 3.64 x 10-6 |