SDS Volume (2372)

Volume 60. Halogenated Methanes with Water, p None

Original Measurements

Freed, V. H.; Chiou, C. T.; Schmedding, D.; Kohnert, R.; Environ. Health Perspect. 1979, 30, 75-80.

Variables:

Room Temp: 298 $\pu{K}$

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

A known volume of water was mixed with trichloromethane in an Erlenmeyer flask. The flask was immersed in a water bath and magnetically stirred. Samples were removed for analysis at regular intervals. All samples were analyzed using a gas-liquid chromatograph equipped with an electron capture detector. The solubility given is the average of five consecutive samples with less than 5 % variation.

Source and Purity of Materials:
  1. Source not given. Analytical standard grade, greater than 95% purity.
  2. Distilled and run through a resin column before use.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): 5% variation of 5 samples.

Components:
  1. Trichloromethane, $\ce{ CHCl3 }$; [67-66-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) w1 100w1 $x_{1}$
25 7.95 x 10-3 0.7951.208 x 10-4

Download Data   link to XML output link to JSON output link to JSON-LD output