SDS Volume (2349)

Volume 60. Halogenated Methanes with Water, p None

Original Measurements

Kudryavtseva, G. I.; Krutikova, A. D.; J. Appl. Chem. USSR 1953, 26, 1129-33.

Variables:

Room Temp: 293 $\pu{K}$

Prepared by:

Z. Maczynska

Method/Apparatus/Procedure:

The mutual solubility between trichloromethane and water was determined by titration from a microburet until turbidity appeared. The end point of the titration, when turbidity first appeared, was determined with an accuracy of 0.3 - 0.5 %. The titration of the solution took place in a thermostat bath at 20 °C. The caprolactam-water-trichloromethane ternary system was also studied.

Source and Purity of Materials:
  1. Source and purity not given.
  2. Distilled (compiler).
Estimated Errors:

Ambient temperature: ±0.5 K (compiler).
Mass concentration (m/v) (1): 0.3 - 0.5.

Components:
  1. Trichloromethane, $\ce{ CHCl3 }$; [67-66-3] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 100w2 $x_{1}$ $x_{2}$
20 0.840.99 1.28 x 10-30.0621

(a) Calculated by the compiler.

Download Data   link to XML output link to JSON output link to JSON-LD output