SDS Volume

Volume 60. Halogenated Methanes with Water, p None

Source Publication

Nicholson, B. C.; Maguire, B. P.; Bursill, D. B.; Environ. Sci. Technol. 1984, 18, 518-21.

Conditions:

Room Temp: 293 $\pu{K}$

Compiler:

A.L. Horvath

Methodology:

The apparatus consisted of a stripping vessel similar to that described by Mackay, et al. [1]. The air entered through the top of the vessel and the diffuser was close to the bottom. The solution was added to the stripping vessel and the desired flow rate maintained. Samples of the solution being stripped were taken for analysis. After samples were extracted, they were analyzed by gas chromatograph equipped with a capillary column.

Sample Information:
  1. Source and purity not given.
  2. pH = 7.6, 370 mg salt/$\pu{dm3}$, 60 mg $\ce{CaCO3}/\pu{dm3}$, 10 mg organic carbon/$\pu{dm3}$.
Measurement Errors:

Ambient temperature: ±0.1 K.
Mass concentration (m/v) (1): Not specified.

Methodology Citation

1 Mackay, D.; Shiu, W. Y.; Sutherland, R. D. Environ. Sci. Technol. 1979, 13, 333.

System Components:
  1. Tribromomethane, $\ce{ CHBr3 }$; [75-25-2] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) 100w1 a $x_{1}$ $k_{\rm{H}}$ (m3 atm mol-1)
20 0.3242.32 x 10-44.1 x 10-4

Download Data   link to XML output link to JSON output link to JSON-LD output