SDS Volume
Volume 37. Hydrocarbons in Water and Seawater, Part I, p 141
Source Publication
Conditions:
Room Temp: 0 - 50 °C
Compilers:
Methodology:
Component (1) was introduced into a thermostatted flask and saturated for 5 hrs. with (2). Next, calcium hydride was added and the evolving hydrogen volume measured and hence the concentration of (2) in (1) was evaluated.
Sample Information:
- Not specified.
- Not specified.
Measurement Errors:
Ambient temperature: Not specified.
System Components:
- Benzene, $\ce{ C6H6 }$; [71-43-2] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | MR2 (g1/100 g2) | $x_{2}$ |
|---|---|---|
| 0 | 0.03996 | 1.730 x 10-3 |
| 10 | 0.0446 | 1.93 x 10-3 |
| 20 | 0.0582 | 2.52 x 10-3 |
| 30 | 0.0749 | 3.24 x 10-3 |
| 40 | 0.0948 | 4.10 x 10-3 |
| 50 | 0.1177 | 5.09 x 10-3 |