SDS Volume

Volume 59. Polycyclic Aromatic Hydrocarbons: Binary Non-aqueous Systems, Part II Solutes F-Z, p None

Source Publication

McLaughlin, E.; Zainal, H. A.; J. Chem. Soc. 1960, 2485-2488.

Conditions:

Room Temp: Temperature $\pu{K}$

Compiler:

W.E. Acree, Jr.

Methodology:

Constant temperature bath and a precision thermometer.
Mixtures of known concentrations sealed in glass ampoules and placed in constant temperature to equilibrate. Samples were rotated while bath temperature slowly increased. Solubility determined by visual noting the same temperature at which the last trace of solid solute disappeared.

Sample Information:
  1. Purity not given, Gesellschaft fur Teerverwertung, was passed over an alumina column with benzene as eluant.
  2. AnalaR Grade, source not given, was dried over anhydrous calcium chloride and distilled before use.
Measurement Errors:

Ambient temperature: T/K: precision ±0.1. x1: ±0.0003 (compiler).

System Components:
  1. Pyrene, $\ce{ C16H10 }$; [129-00-0] NIST WebBook
  2. Tetrachloromethane, $\ce{ CCl4 }$; [56-23-5] NIST WebBook
Experimental Data
$T$ ($\pu{K}$) $x_{1}$ $x_{2}$
314.2 0.07020.9298
331.6 0.11890.8811
342.2 0.16390.8361
352.4 0.21900.7810

Download Data   link to XML output link to JSON output link to JSON-LD output