SDS Volume
Volume 59. Polycyclic Aromatic Hydrocarbons: Binary Non-aqueous Systems, Part II Solutes F-Z, p None
Source Publication
Djordjevic, N. M.; Thermochim. Acta 1991, 177, 109-118.
Conditions:
Room Temp: Temperature $\pu{K}$
Compiler:
Methodology:
Differential scanning calorimeter.
Mixtures (1.5 - 2.0 mg) of known concentration were weighed into alumina pans, which were then crimped to preclude sample loss during the heating process. Solubilities determined by measuring melting points of binary mixtures using a PerkinElmer DSC-2 differential scanning calorimeter and scan rate of 5 k/min.
Sample Information:
- Gold Label, 99+%, Aldrich Chemical Company, Milwaukee, Wisconsin, USA, was used as received.
- 99%, Aldrich Chemical Company, was vacuum-distilled before use.
Measurement Errors:
Ambient temperature: T/K: precision ±0.3 (compiler). x1: ±0.0003 (compiler).
System Components:
- Pyrene, $\ce{ C16H10 }$; [129-00-0] NIST WebBook
- Octadecane, $\ce{ C18H38 }$; [593-45-3] NIST WebBook
Experimental Data
| $T$ ($\pu{K}$) | $x_{1}$ | $x_{2}$ |
|---|---|---|
| 407.0 | 0.6061 | 0.3939 |
| 409.1 | 0.6905 | 0.3095 |
| 409.7 | 0.7028 | 0.2972 |
| 410.5 | 0.7329 | 0.2671 |
| 411.2 | 0.7612 | 0.2388 |
| 412.5 | 0.8235 | 0.1765 |
| 417.2 | 0.8986 | 0.1014 |
| 419.0 | 0.9502 | 0.0498 |