SDS Volume
Volume 20. Halogenated Benzenes, Toluenes and Phenols with Water, p 137
Source Publication
Gross, P. M.; Saylor, J. H.; J. Am. Chem. Soc. 1931, 53, 1744-51.
Conditions:
Room Temp: 30 °C
Compiler:
Methodology:
An excess of bromobenzene in 500 g water was shaken for 12 hrs. in a thermostat bath. Samples were then withdrawn and read against water in an interferometer made by Zeiss [1]. A detailed description of the complete procedure is given in a Ph.D. dissertation [1].
Sample Information:
- Eastman Kodak Co., was purified by fractional distillation before use.
- Distilled.
Measurement Errors:
Ambient temperature: ±0.02 K.
Mass concentration (m/v) (1): ±2%.
Methodology Citations
1
Gross, P. M.; J. Am. Chem. Soc. 1929, 51, 2362-6.
2
Saylor, J. H.; Ph.D. Dissertation, Duke University, Durham, NC, 1930.
System Components:
- Bromobenzene, $\ce{ C6H5Br }$; [108-86-1] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | $x_{1}$ | MR1 (g/kg) | m1 (mol/kg) |
|---|---|---|---|
| 30 | 5.117 x 10-5c | 0.446 | 2.839 x 10-3b |
(a) Reported.
(b) Calculated by F. W. Getzen.
(c) Calculated by the compiler.