SDS Volume

Volume 20. Halogenated Benzenes, Toluenes and Phenols with Water, p 137

Source Publication

Gross, P. M.; Saylor, J. H.; J. Am. Chem. Soc. 1931, 53, 1744-51.

Conditions:

Room Temp: 30 °C

Compiler:

A.L. Horvath

Methodology:

An excess of bromobenzene in 500 g water was shaken for 12 hrs. in a thermostat bath. Samples were then withdrawn and read against water in an interferometer made by Zeiss [1]. A detailed description of the complete procedure is given in a Ph.D. dissertation [1].

Sample Information:
  1. Eastman Kodak Co., was purified by fractional distillation before use.
  2. Distilled.
Measurement Errors:

Ambient temperature: ±0.02 K.
Mass concentration (m/v) (1): ±2%.

Methodology Citations

1 Gross, P. M.; J. Am. Chem. Soc. 1929, 51, 2362-6.
2 Saylor, J. H.; Ph.D. Dissertation, Duke University, Durham, NC, 1930.

System Components:
  1. Bromobenzene, $\ce{ C6H5Br }$; [108-86-1] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $x_{1}$ MR1 (g/kg) m1 (mol/kg)
30 5.117 x 10-5c0.4462.839 x 10-3b

(a) Reported.

(b) Calculated by F. W. Getzen.

(c) Calculated by the compiler.

Download Data   link to XML output link to JSON output link to JSON-LD output