Components:

(1) 1,3-Dichlorobenzene, C6H4C12; [541-73-1] NIST WebBook
(2) Water, H2O; [7732-18-5] NIST WebBook

Original Measurements

Schwarz, F. P.; Miller, J.; Anal. Chem. 1980, 52(13), 2162-4.

Variables:

Ambient temperature: Temperature

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

Both elution chromatography and UV absorption methods were used to determine the aqueous solubilities. The agreement was within an experimental error of 4% between the two methods. The average deviations were determined from several measurements made on different samples. The analytical procedures for determining organic liquid solubilities in water based on liquid phase elution chromatography has been described in (1).

Source and Purity of Materials:
  1. Commercial, 98 wt.%.
  2. distilled.
Estimated Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±4%.

References

1 Schwarz, F. P.; Anal. Chem. 1980, 52, 10-15.

Experimental Values:
Experimentally determined values:
T (°C) MR1 (g/kg)
10.0 1.16 x 10-1
20.0 8.9 x 10-2
30.0 1.39 x 10-1
10.0 1.20 x 10-1
20.0 1.13 x 10-1
30.0 1.32 x 10-1

(a) Reported. (b) Calculated by F. W. Getzen. (c) Calculated by the compiler.

Values derived fdrom average measured solubilities:
T (°C) x1 MR1 (g/kg) m1 (mol/kg)
10.0 1.446 x 10-5 1.18 x 10-1 8.027 x 10-4
20.0 1.238 x 10-5 1.01 x 10-1 6.870 x 10-4
30.0 1.655 x 10-5 1.35 x 10-1 9.183 x 10-4