SDS Volume (2046)

Volume 59. Polycyclic Aromatic Hydrocarbons: Binary Non-aqueous Systems, Part II Solutes F-Z, p None

Original Measurements

McLaughlin, E.; Zainal, H. A.; J. Chem. Soc. 1960, 2485-2488.

Variables:

Room Temp: Temperature $\pu{K}$

Prepared by:

W.E. Acree, Jr.

Method/Apparatus/Procedure:

Constant temperature bath and a precision thermometer.
Mixtures of known concentrations sealed in glass ampoules and placed in constant temperature to equilibrate. Samples were rotated while bath temperature slowly increased. Solubility determined by visual noting the same temperature at which the last trace of solid solute disappeared.

Source and Purity of Materials:
  1. Purity not given, British Drug Houses, United Kingdom, was passed over an alumina column with benzene as eluant.
  2. AnalaR grade, source not given, was stored over anhydrous calcium chloride and distilled before use.
Estimated Errors:

Ambient temperature: T/K: precision ±0.1. x1: ±0.0003 (compiler).

Components:
  1. Phenanthrene, $\ce{ C14H10 }$; [85-01-8] NIST WebBook
  2. Tetrachloromethane, $\ce{ CCl4 }$; [56-23-5] NIST WebBook
Experimental Data
$T$ ($\pu{K}$) $x_{1}$ $x_{2}$
305.6 0.17680.8232
310.0 0.20840.7916
314.0 0.24210.7579
317.0 0.26640.7336
319.2 0.29200.7080

Download Data   link to XML output link to JSON output link to JSON-LD output