Components:
(1) 1,3-Dichlorobenzene,
C6H4C12; [541-73-1]
NIST WebBook
(2) Water,
H2O; [7732-18-5]
NIST WebBook
Original Measurements
Vesala, A.; Acta Chem. Scand. 1974, 28A(8), 839-845.
Variables:
Ambient temperature: One temperature
Prepared by:
Method/Apparatus/Procedure:
Equilibrium was established between the water and the 1,3-dichlorobenzene in a sealed flask (1) with the aid of a magnetic stirrer during 48 hours under isothermal conditions. After the sample was filtered through a glass-wool plug, the 1,3-dichlorobenzene was extracted with 2,2, 4-trimethylpentene. Sample optical densities were determined spectrophotometrically (2). Five parallel determinations were done. The reported work was based upon a Ph.D. dissertation (3).
Source and Purity of Materials:
- Commercial reagent of analytical grade distilled through a column resulting in a more than 99% pure sample.
- Distilled, deionized, and degassed.
Estimated Errors:
Ambient temperature: ±0.05 K.
Mass concentration (m/v) (1): ±1.0%.
References
1
Franks, F.; Gent, M.; Johnson, H. H.; J. Chem. Soc. 1963, 2716-23.
2
Wauchope, R. D.; Getzen, F. W.; J. Chem. Eng. Data 1972, 17(1), 38-41.
3
Vesala, A.; Ph.D. Dissertation, University of Turku, Turku, 1973.
Experimental Values:
| T (°C) | x1 | MR1 (g/kg) | m1 (mol/kg) |
|---|---|---|---|
| 25.0 | 1.261 x 10-5 | 1.029 x 10-1 | 7.00 x 10-4 |
(a) Calculated by the compiler. (b) Reported.