Components:

(1) 1,3-Dichlorobenzene, C6H4C12; [541-73-1] NIST WebBook
(2) Water, H2O; [7732-18-5] NIST WebBook

Original Measurements

Vesala, A.; Ph.D. Dissertation, University of Turku, Turku, 1973.

Variables:

Ambient temperature: Temperature

Prepared by:

A.L. Horvath

Method/Apparatus/Procedure:

The 1,3-dichlorobenzene was mixed with water in a sealed flask (1) with the aid of a magnetic stirrer for 48 hours in a water bath at constant temperature. After the solution was filtered through a glass-wool plug, the solute was extracted with 2, 2, 4-trimethylpentene. The optical density of each sample was determined spectrophotometrically (2). Mean and standard deviations were calculated from three measurements.

Source and Purity of Materials:
  1. Fluka AG, puriss, >99% GLC, used as received.
  2. Distilled, deionized, and degassed.
Estimated Errors:

Ambient temperature: ±0.05 K.
Mass concentration (m/v) (1): ±1.93%.

References

1 Franks, F.; Gent, M.; Johnson, H. H.; J. Chem. Soc. 1963, 2716-23.
2 Wauchope, R. D.; Getzen, F. W.; J. Chem. Eng. Data 1972, 17(1), 38-41.

Experimental Values:
T (°C) x1 MR1 (g/kg) m1 (mol/kg)
10.0 1.1966 x 10-5 9.7632 x 10-2 6.642 x 10-4
15.2 1.1982 x 10-5 9.7764 x 10-2 6.651 x 10-4
19.6 1.2051 x 10-5 9.8323 x 10-2 6.689 x 10-4
25.1 1.2411 x 10-5 1.0126 x 10-1 6.889 x 10-4
30.0 1.3818 x 10-5 1.1274 x 10-1 7.670 x 10-4
35.0 1.4847 x 10-5 1.2113 x 10-1 8.241 x 10-4

(a) Calculated by the compiler. (b) Reported.