SDS Volume

Volume 20. Halogenated Benzenes, Toluenes and Phenols with Water, p 88

Source Publication

Chiou, C. T.; Schmedding, D. W.; Manes, M.; Environ. Sci. Technol. 1982, 16(1), 4-10.

Conditions:

Room Temp: 25 °C

Compiler:

A.L. Horvath

Methodology:

An excess of 1,2-dichlorobenzene was equilibrated with water in screwcapped bottles in a reciprocal shaker for 24 hours. After two days settling, samples were taken from the solution for analysis by gas chromatography. The chromatograph was equipped with a $\ce{^{63}Ni}$ EC detector. Analyses were continued until a constant concentration was observed.

Sample Information:
  1. Not specified.
  2. distilled.
Measurement Errors:

Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±5% (compiler).

System Components:
  1. 1,2-Dichlorobenzene, $\ce{ C6H4Cl2 }$; [95-50-1] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
$T$ (°C) $x_{1}$ $C_{1}$ (mol/dm3)
25 1.8921 x 10-5c1.047 x 10-3

(a) Calculated by F. W. Getzen.

(b) Reported.

(c) Calculated by the compiler.

Download Data   link to XML output link to JSON output link to JSON-LD output