SDS Volume
Volume 20. Halogenated Benzenes, Toluenes and Phenols with Water, p 88
Source Publication
Chiou, C. T.; Schmedding, D. W.; Manes, M.; Environ. Sci. Technol. 1982, 16(1), 4-10.
Conditions:
Room Temp: 25 °C
Compiler:
Methodology:
An excess of 1,2-dichlorobenzene was equilibrated with water in screwcapped bottles in a reciprocal shaker for 24 hours. After two days settling, samples were taken from the solution for analysis by gas chromatography. The chromatograph was equipped with a $\ce{^{63}Ni}$ EC detector. Analyses were continued until a constant concentration was observed.
Sample Information:
- Not specified.
- distilled.
Measurement Errors:
Ambient temperature: ±0.5 K.
Mass concentration (m/v) (1): ±5% (compiler).
System Components:
- 1,2-Dichlorobenzene, $\ce{ C6H4Cl2 }$; [95-50-1] NIST WebBook
- Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data
| $T$ (°C) | $x_{1}$ | $C_{1}$ (mol/dm3) |
|---|---|---|
| 25 | 1.8921 x 10-5c | 1.047 x 10-3 |
(a) Calculated by F. W. Getzen.
(b) Reported.