Components:
(1) Buckminsterfullerene,
C60; [99685-96-8]
NIST WebBook
(2) 2-methylthiophene,
C5H6S; [554-14-3]
NIST WebBook
Original Measurements
Ruoff, R. S.; Tse, D. S.; Malhotra, R.; Lorents, D. C.; J. Phys. Chem. 1993, 97, 3379-3383.
Variables:
Ambient temperature: Circa 295 (Ambient Room)
Prepared by:
Method/Apparatus/Procedure:
High performance liquid chromatograph system equipped with an ultraviolet detector and integrator. Excess solute and solvent placed in 1-dram glass bottle and allowed to equilibrate for 24 hours at ambient room temperature with agitation. Saturated solution was filtered through a 0.45 micrometer poly-(tetrafluoroethylene) filter. Concentrations determined via HPLC with uv detection at 340 nm. Stationary phase was a dinitroanilinopropyl column, and a binary toluene/hexane (20:80 by volume) mobile phase was used.
Source and Purity of Materials:
- Graphite soot obtained by passing an ac discharge between spectroscopic grade graphite, and sample purified by chromatographic separation on alumina column. Final purity of 99.95% as determined by mass spectrometry.
- Reagent grade, 99% (or better), chemical source not given, used as received from manufacturer.
Estimated Errors:
Ambient temperature: T/K: ±3.
Mole fraction - Liquid (1): x1: ±8% (relative error; compiler).
Experimental Values:
| T (°C) | x1 |
|---|---|
| 22.0 | 9.1 x 10-4 |