SDS Volume
Volume 58. Polycyclic Aromatic Hydrocarbons: Binary Non-aqueous Systems, Part I Solutes A-E, p 225
Source Publication
Conditions:
Room Temp: 303 $\pu{K}$
Compiler:
Methodology:
Constant temperature bath, stirrer, thermometer, and an ultraviolet/visible spectrophotometer. Excess solute and solvent placed in glass tube and allowed to equilibrate for 5 hours at constant temperature with stirring. Tube was then centrifuged and aliquots of saturated solution was with- drawn and the absorbance measured at 328 nm after appropriate dilution with spectroscopic grade n-hexane.
Sample Information:
- Graphite soot obtained by passing an ac discharge between spectroscopic grade graphite, fullerness recovered by soxhlet extraction with toluene, and sample purified by chromatographic separation on alumina column.
- HPLC grade or AR grade solvent, chemical source not given, aromatic impurities removed by chromatography if necessary.
Measurement Errors:
Ambient temperature: T/K: ±0.1.
Mass concentration (m/v) (1): c1: ±3% (relative error; compiler).
System Components:
- Buckminsterfullerene, $\ce{ C60 }$; [99685-96-8] NIST WebBook
- Dichloromethane, $\ce{ CH2Cl2 }$; [75-09-2] NIST WebBook
Experimental Data
| $T$ (°C) | $C_{1}$ (mol/dm3) |
|---|---|
| 30.0 | 3.52 x 10-4 |