Components:

(1) Ethylene, C2H4; [74-85-1] NIST WebBook
(2) Phenol, C6H6O; [108-95-2] NIST WebBook

Original Measurements

Lenoir, J-Y.; Renault, P.; Renon, H.; J. Chem. Eng. Data 1971, 16, 340-2.

Variables:

Ambient temperature: 323.2 K
Pressure: 101.3 kPa

Prepared by:

C.L. Young

Method/Apparatus/Procedure:

A conventional gas-liquid chromatographic unit fitted with a thermal conductivity detector was used. The carrier gas was helium. The value of Henry's law constant was calculated from the retention time. The value applies to very low partial pressures of gas and there may be a substantial difference from that measured at 1 atm. pressure. There is also considerable uncertainty in the value of Henry's constant since surface adsorption was not allowed for although its possible existence was noted.

Source and Purity of Materials:
  1. L'Air Liquide sample, minimum purity 99.9 mole%.
  2. Touzart and Matignon or Serlabo sample, purity 99 mole%.
Estimated Errors:

Ambient temperature: δT/K = ±0.1 (estimated by compiler)
Mass concentration (m/v) (1): δH/atm = ±6% (estimated by compiler)

Experimental Values:
T (K) x1 H (atm)
323.2 3.86 x 10-3 259.0

(a) Calculated by compiler assuming a linear function of HC2H4 vs. xC2H4' i.e., xC2H4 (1 atm) =

Download Data   link to XML output link to JSON output link to JSON-LD output