SDS Volume
Volume 57. Ethene, p 188
Source Publication
Boyer, F. L.; Bircher, L. J.; J. Phys. Chem. 1960, 64, 1330 - 1331.
Conditions:
Room Temp:
298.15
$\pu{K}$
Pressure:
101.325
$\pu{kPa}$
Compilers:
Methodology:
A commercial Van Slyke blood gas apparatus (E. H. Sargent Co.) was modified by the authors.
The total pressure of the gas and the solvent vapor in the solution chamber was adjusted to a pressure of one atm. The pressure was maintained at one atm during the solution process. The saturated solution was transferred to a bulb below the lower stopcock of the extraction vessel and sealed off. The gas and solvent vapor were then brought to volume over mercury. See (2) for details of the extraction procedure.
Sample Information:
- Ethene. Matheson Co. Stated to be 99.5 mol%.
- Ethanol. Source not given. Treated by standard methods to remove aldehydes and ketones, then dried and distilled.
Measurement Errors:
Ambient temperature: δT/K = ±0.01
Mass concentration (m/v) (1): δL/cm3 = ±0.02
Methodology Citations
1
Boyer, F. L.; Ph.D. Dissertation, 1959, Vanderbilt Univ., Nashville, TN.
2
Peters, J. P.; Van Slyke, D. D.; Quantitative Clinical Chemistry, Baltimore, MD, 1932, Volume II.
System Components:
- Ethene, $\ce{ C2H4 }$; [74-85-1] NIST WebBook
- Ethanol, $\ce{ C2H6O }$; [64-17-5] NIST WebBook
Experimental Data
The Bunsen coefficient was calculated by the compiler.
The mole fraction solubility was taken from Boyer's thesis1.
See the methanol data sheet for the equations relating the mole fraction solubility and the number of normal alcohol carbon numbers.
| $T$ ($\pu{K}$) | $x_{1}$ | $L$ | α ($\pu{cm3(g) cm-3(l) atm-1}$) |
|---|---|---|---|
| 298.15 | 6.14 x 10-3 | 2.56 | 2.341 |
(1) α/cm3 (STP) cm-3 atm-1