Volume 38. Hydrocarbons in Water and Seawater, Part II, p None

Original Measurements

Davis, W. W.; Krahl, M. E.; Cloves, G. H. A.; J. Am. Chem. Soc. 1942, 64, 108-10.

Variables:

Room Temp: 27 °C

Prepared by:

M.C. Haulait-Pirson

Method/Apparatus/Procedure:

The method consisted of preparing serial dilutions of a suspension of [1] in [2] and determining nephelometrically the amount of [1] per unit volume beyond which further dilution caused no reduction in light scattering, which remained equal to that of pure [2]. A Bausch and Lomb Dubosque colorimeter model 100-mm was employed. Many details are reported in [1].

Source and Purity of Materials:
  1. Prepared at Harvard University; MP = 82.6-83.3°C (cf. [2]).
  2. Dust-free.
Estimated Errors:

Ambient temperature: ±3°C
Mass concentration (m/v) (1): See above.

References

1 Davis, W. W.; Parker Jr., T. V.; J. Am. Chem. Soc. 1942, 64, 101.
2 Davis, W. W.; Krahl, M. E.; Cloves, G. H. A., J. Am. Chem. Soc. 1940, 62, 3086.

Components:
  1. 7-Pentyl-benz[a]anthracene, $\ce{ C23H22 }$; [63019-00-1] NIST WebBook
  2. Water, $\ce{ H2O }$; [7732-18-5] NIST WebBook
Experimental Data

The best value recommended by the authors is 8 × 10-7 g(1) L-1 (2).
With the assumption that 1.00 L sln = 1.00 kg sln, the corresponding mass percent and mole fraction, x1, calculated by the compiler are 8 × 10-8 g(1)/100 g sln and 5 × 10-11.

Solubility of 10-penthylbenz[a]anthracene in water