{"compilation": {"title": "Solubility data from IUPAC SDS Volume 37 (page 475) - 2,4-Dimethylpentane with Water", "publisher": "The International Union of Pure and Applied Chemistry", "keywords": "Solubility, Solubility data series", "compilers": "Marie C. Haulait-Pirson", "sources": [{"citation": "Krzyzanowska, T.; Szeliga, J.; Nafta (Katowice) 1978, 12, 413-7.", "pubtype": "paper"}], "system": "2,4-Dimethylpentane with Water", "substances": [{"constituent": 1, "name": "2,4-Dimethylpentane", "formula": "C7H16", "molweight": 100.202, "casrn": "108-08-7", "inchi": "InChI=1S/C7H16/c1-6(2)5-7(3)4/h6-7H,5H2,1-4H3", "inchikey": "BZHMBWZPUJHVEE-UHFFFAOYSA-N", "sample": "Not specified."}, {"constituent": 2, "name": "Water", "formula": "H2O", "molweight": 18.0153, "casrn": "7732-18-5", "inchi": "InChI=1S/H2O/h1H2", "inchikey": "XLYOFNOQVPJJNP-UHFFFAOYSA-N", "sample": "Not specified."}], "method": "Saturated solutions of (1) in (2) were prepared in two ways. First, 200 microliters of (1) was injected into 20 mL of (2) and thermostatted at 25 \u00b0C. Second the mixture, of (1) and (2) as above was thermostatted at 70 \u00b0C and then cooled to 25 \u00b0C. The time required to obtain equilibrium was three weeks. The solubility of () in (2) was measured by glc. A Perkin-Elmer model F-11 gas chromatograph equipped with a 100-150 mesh Porasil column (70 \u00b0C) and a flame ionization detector was used. Saturated solutions of heptane in (2) were used as standard solutions.", "dataset": []}}