{"compilation": {"title": "Solubility data from IUPAC SDS Volume 38 (page ?) - Pyrene with Water", "publisher": "The International Union of Pure and Applied Chemistry", "keywords": "Solubility, Solubility data series", "compilers": "Marie C. Haulait-Pirson", "sources": [{"citation": "Mackay, D.; Shiu, W. Y.; J. Chem. Eng. Data. 1977, 22, 399-402.", "pubtype": "paper", "url": "https://doi.org/10.1021/je60075a012"}], "system": "Pyrene with Water", "substances": [{"constituent": 1, "name": "Pyrene", "formula": "C16H10", "molweight": 202.251, "casrn": "129-00-0", "inchi": "InChI=1S/C16H10/c1-3-11-7-9-13-5-2-6-14-10-8-12(4-1)15(11)16(13)14/h1-10H", "inchikey": "BBEAQIROQSPTKN-UHFFFAOYSA-N", "sample": "Aldrich Chemicals, Eastman Kodak, or K and K Laboratories, commercial highest grade; used as received."}, {"constituent": 2, "name": "Water", "formula": "H2O", "molweight": 18.0153, "casrn": "7732-18-5", "inchi": "InChI=1S/H2O/h1H2", "inchikey": "XLYOFNOQVPJJNP-UHFFFAOYSA-N", "sample": "Doubly distilled"}], "method": "A saturated solution of (1) in (2) was vigorously stirred in a 250 mL flask for 24 hrs. and subsequently settled at 25 \u00b0C for at least 48 hrs. Then the saturated solution was decanted and filtered and 50-100 mL extracted with approximately 5 mL of cyclohexane in a separatory funnel. After shaking for 2 hrs. the cyclohexane extract was removed for analysis. An Aminco-Browman spectrophotofluorometer (American Instruments Ltd.) was used for analysis. Many details are given in the paper.", "dataset": []}}