{"compilation": {"title": "Solubility data from IUPAC SDS Volume 60 (page ?) - Bromochloromethane with Water", "publisher": "The International Union of Pure and Applied Chemistry", "keywords": "Solubility, Solubility data series", "compilers": "Ari L. Horvath", "sources": [{"citation": "Tewari, Y. B.; Miller, M. M.; Wasik, S. P.; Martire, D. E.; J. Chem. Eng. Data 1982, 27, 451-4.", "pubtype": "paper", "url": "https://doi.org/10.1021/je00030a025"}], "system": "Bromochloromethane with Water", "substances": [{"constituent": 2, "name": "Water", "formula": "H2O", "molweight": 18.0153, "casrn": "7732-18-5", "inchi": "InChI=1S/H2O/h1H2", "inchikey": "XLYOFNOQVPJJNP-UHFFFAOYSA-N", "sample": "Baker-analyzed HPLC grade."}, {"constituent": 1, "name": "Bromochloromethane", "formula": "CH2BrCl", "molweight": 129.384, "casrn": "74-97-5", "inchi": "InChI=1S/CH2BrCl/c2-1-3/h1H2", "inchikey": "JPOXNPPZZKNXOV-UHFFFAOYSA-N", "sample": "Source not known, at least 99% pure by GC analysis."}], "method": "The modified generator column method was used. A chromatographic column was coated with bromochloromethane. An aqueous phase was generated by pumping water through the coated generator column. The aqueous solution was analyzed by a gas chromatography. The gas chromatograph was equipped with a flame ionization detector. On average, at least three measurements were taken.", "dataset": [{"series": 1, "points": [{"pntnum": 1, "conditions": [{"property": "Ambient temperature", "number": "2.50e+01", "significand": "2.50", "exponent": "1", "sigfigs": "3", "unit": "&deg;C"}], "data": [{"property": "Amount concentration (1)", "number": "1.25e+02", "significand": "1.25", "exponent": "2", "sigfigs": "3", "unit": "mol/m3"}], "supplemental": [{"property": "Percent mass fraction (1)", "number": "1.646e+00", "significand": "1.646", "exponent": "0", "sigfigs": "4", "unit": "1"}, {"property": "Mole fraction - Liquid (1)", "number": "2.325e-03", "significand": "2.325", "exponent": "-3", "sigfigs": "4", "unit": "1"}]}]}]}}